Arnoldstraße 19 • 47906 Kempen, Germany  +49 2152 8955-0  vertrieb@alders.de

Logo Alders Electronic GmbH

Gas sensors

For the measurement of gas in the ambient air, we rely on gas sensors from our premium partner FES Sensor Technology. As an expert in hydrogen sensor technology with many years of experience, FES offers innovative calibrated hydrogen sensors that are insensitive to siloxanes. Typical applications of our hydrogen sensors are areas in which hydrogen is produced, stored, transported and used. FES offers hydrogen sensors for industrial leak detection, fuel cell, laboratory, automotive and many other applications. The gas sensors are characterized by the following properties, among others:

  • high robustness and long service life
  • absolutely maintenance-free
  • high sensitivity and selectivity to hydrogen up to the lower explosive limit (LEL)
  • insensitive to typical catalyst poisons such as volatile siloxanes and carbon monoxide

For the detection of other target gases (including methane, liquid gas and CO2 detection) we rely on innovative sensors from the world’s leading manufacturer NISSHA FIS Inc. The high-quality sensors are characterized by excellent stability and high sensitivity. In addition, they are maintenance-free. Gas sensors in general contribute to a safe environment and are used wherever gases are produced, stored, transported and used. In industry, for example, the use of gas sensors is important for compliance with safety regulations.

FES Sensor Technology Hydrogen-Sensor H2-CNI I2C-E-ULTD

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • Extended temperature range from -40 °C to +120 °C
  • Ultralow thermal drift
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Linear output up to 100 % LEL
  • No cross-sensitivity against hydrocarbons such as methane and ethane
  • On-board digital temperature sensor and EEPROM with I2C®bus connectivity

Nissha FIS Inc. Gas sensors SP-12A-00 für LNG(Methan)

Usage:Home gas leak detector

Target gasLNG(Methane)
DescriptionSensor with high selectivity to methane. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ17.0 x 16.5mm
Weight0.6g

Nissha FIS Inc. Gas sensor SB-12A-00 for Methane (LNG)

Usage:Home gas leak detector/Industrial leak detector

  • Target gas: Methane (LNG), H2
  • Description: Compact, low power consumption sensor with excellent methane selectivity.
  • Sensing principal: Semiconductor type
  • Standard operating condition: Heater voltage/DC 0.9V ± 5% & Circuit voltage/less than DC 5V
  • Power consumption: 120mW
  • Filter: Charcoal filter
  • Size: φ10.0 x 20mm
  • Weight: 1.2g
SB-11A-00

Nissha FIS Inc. Gas sensor SB-15-00 for LPG (Propane, butane)

Usage: Industrial leak detector

  • Target gas: LPG(Propane, butane)
  • Description: Compact, low power consumption, excellent responsiveness, and highly sensitive sensor for propane LPG/butane
  • Sensing principal: Semiconductor type
  • Standard operating condition: Heater voltage/DC 0.9V ± 5% & Circuit voltage/less than DC 5V
  • Power consumption: 120mW
  • Filter: Not included
  • Size: φ7.6 x 13.4mm
  • Weight: 0.6g

Nissha FIS Inc. Gas sensor SB-15B-00 for LPG (Propane, Butane)/Refrigerant(R290)

Usage: Industrial leak detector

  • Target gas: LPG(Propane, butane)
  • Description: Compact, low power consumption, excellent responsiveness, and highly sensitive sensor for propane LPG/butane
  • Sensing principal: Semiconductor type
  • Standard operating condition: Heater voltage/DC 0.9V ± 5% & Circuit voltage/less than DC 5V
  • Power consumption: 120mW
  • Filter: Not included
  • Size: φ9.7 x 15.7mm
  • Weight: 1.1g

Nissha FIS Inc. Gas sensor SB-500-12 for Carbon monoxide

Usage:Home gas leak detector/Industrial leak detector

Target gasCarbon monoxide (CO)
DescriptionSensor with high sensitivity and long life to carbon monoxide. UL compliant product
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V x 5sec. + DC 0.2V x 20sec.        Circuit voltage/less than DC 5V
Power consumptionAverage:34mW
FilterCharcoal filter
Sizeφ10.0 x 20mm
Weight1.2g

Nissha FIS Inc. Gas sensor SB-96-00 for LPG (Propane, butane) / Carbon monoxide (CO)

Usage:Home gas leak detector/Industrial leak detector

Target gasLPG(Propane, butane), Carbon monoxid (CO)
DescriptionA sensor that can selectively detect propane and CO only with one sensor element
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V x 5sec. + DC 0.2V x 20sec.                 Circuit voltage/less than DC 5V
Power consumptionAverage:34mW
FilterSilica filter
Sizeφ9.7 x 15.7mm
Weight1.1g

Nissha FIS Inc. Gassensor SP-53B-00 for Ammonia

Usage:Refrigerant gas/Home appliances/Industrial leak detector

Target gasAmmonia
DescriptionSensor for detecting high concentration ammonia. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ17.0 x 16.5mm
Weight1.75g

Nissha FIS Inc. Gas sensor SB-95-12 for Methane (LNG) / Carbon monoxide (CO)

Usage:Home gas leak detector/Industrial leak detector

  • Target gas: LNG (Methane), Carbon Monoxide (CO)
  • Description: A sensor that can selectively detect methane and CO only with one sensor element. UL compliant product
  • Sensing principal: Semiconductor type
  • Standard operating condition: Heater voltage/DC 0.9V x 5sec. + DC 0.2V x 20sec. & Circuit voltage/less than DC 5V
  • Power consumption: Average: 34mW
  • Filter: Charcoal filter
  • Size: φ10.0 x 20mm
  • Weight: 1.2g

Nissha FIS Inc. Gas sensor SB-51-00 for Hydrogen sulfide

Usage:Industrial leak detector
  • Target gas: Hydrogen sulfide
  • Description: Sensor that is higly sensitive to hydrogen sulfide
  • Sensing principal: Semiconductor type
  • Standard operating condition: Heater voltage/DC 0.9V ± 5% & Circuit voltage/less than DC 5V
  • Power consumption: 120mW
  • Filter: Not included
  • Size: φ7.6 x 13.4mm
  • Weight: 0.6g

Nissha FIS Inc. Gas sensor SB-31-00 for Solvents/VOC

Usage:Industrial leak detector

  • Target gas: VOC
  • Description: Compact, low power consumption sensor with high sensitivity to various VOCs. Suitable for continuous operation products.
  • Sensing principal: Semiconductor type
  • Standard operating condition: Heater voltage/DC 0.9V ± 5% & Circuit voltage/less than DC 5V
  • Power consumption: 120mW
  • Filter: Not included
  • Size: φ7.6 x 13.4mm
  • Weight: 0.6g

Nissha FIS Inc. Gas sensor SB-19-00 for H2

Usage:Industrial leak detector

Target gasH2
DescriptionCompact, low power consumption sensor with excellent H2 selectivity.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption120mW
FilterNot included
Sizeφ7.6 x 13.4mm
Weight0.6g

Nissha FIS Inc. Gas sensor SB-41A-00 for Refrigerant Gas (R22)

Usage:Refrigerant gas / Industrial leak detector

Target gasRefrigerant gas(R22)
DescriptionCompact, low power consumption, excellent responsiveness, and highly sensitive sensor for R22.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption120mW
FilterNot included
Sizeφ9.7 x 15.7mm
Weight1.1g

Nissha FIS Inc. Gas sensors SB-42A-00 for Refrigerant Gas

Usage:Refrigerant gas/Industrial leak detector

Target gasRefrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
DescriptionCompact, low power consumption, highly responsive sensor that is highly sensitive to various refrigerant gases.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption120mW
FilterNot included
Sizeφ7.6 x 13.4mm
Weight0.6g

Nissha FIS Inc. Gas sensors SB-42A-00 for Refrigerant Gas

Target gas:Refrigerant(R32/R410a/R407C/R1234yf/R454B/R454C/R290/Others)

Target gasRefrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
DescriptionCompact sensor that is highly sensitive to various refrigerant gases with low power consumption and excellent durability
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption120mW
FilterSilica filter
Sizeφ10.0 x 20mm
Weight1.2g

Nissha FIS Inc. Gas sensors SB-53-01 for Ammonia

Usage:Research・Analysis – Enviromental measurement

Target gasAmmonia
DescriptionCompact sensor that is highly sensitive to ammonia with low power consumption and excellent response
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption120mW
FilterNot included
Sizeφ7.6 x 13.4mm
Weight0.6g

Nissha FIS Inc. Gas sensors SB-AQ1-06 for H2/Ethanol/VOC

Usage:Automobile – Inside air/Air quality – Air purifiers

Target gasH2、Ethanol、VOC
DescriptionCompact sensor that is highly sensitive to gas generated in a living space with low power consumption and excellent response
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption120mW
FilterNot included
Sizeφ7.6 x 13.4mm
Weight0.6g

Nissha FIS Inc. Gas sensors SB-30-04 for Ethanol/VOC/Halitosis

Usage:Alcohol checker

Target gasVOC、Breath gas
DescriptionSensor that is highly stable after power-on and highly sensitive to alcohol and various VOCs. Suitable for intermittent operation products.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption120mW
FilterNot included
Sizeφ7.6 x 13.4mm
Weight0.6g

Nissha FIS Inc. Gas sensors SP-11-00 for LNG(Methane)/LPG(Propane, butane)/H2

Usage:Home gas leak detector

Target gasLNG(Methane),LPG(Propane, butane),H2
DescriptionSensor that is highly sensitive to various hydrocarbons. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ17.0 x 16.5mm
Weight1.75g

Nissha FIS Inc. Gas sensors SP-15-00 for LPG (Propane, Butane)

Usage:Home gas leak detector

Target gasLPG(Propane, butane)
DescriptionSensor with high selectivity to propane. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ17.0 x 16.5mm
Weight1.75g

Nissha FIS Inc. Gas sensors SP-19-01 for H2

Usage:Industrial leak detector

Target gasH2
DescriptionSensor with high selectivity to H2. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ17.0 x 16.5mm
Weight1.75g

Nissha FIS Inc. Gas sensors SP-41-00 for Refrigerant gas(R22)

Usage:Refrigerant gas/Industrial leak detector

Target gasRefrigerant gas(R22)
DescriptionSensor that is highly sensitive to R22. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ17.0 x 16.5mm
Weight1.75g

Nissha FIS Inc. Gas sensors SP-42A-00 for Refrigerant gas

Usage:Refrigerant gas/Industrial leak detector

Target gasRefrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
DescriptionSensor with excellent response and high sensitivity to various refregerant gases. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ17.0 x 16.5mm
Weight1.75g

Nissha FIS Inc. Gas sensors SP-42AF-00 for Refrigerant gas

Usage:Refrigerant gas/Industrial leak detector

arget gasRefrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
DescriptionSensor with high durability and high sensitivity to various refrigerant gases. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterSilica filter
Sizeφ17.2 x 23.3mm
Weight3.4g

FES Sensor Technology Gassensoren Hydrogen-Sensor H2-CNI 4-20mA-I & H2-CNI 4-20mA-I ULTD

  • Accurate detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air
  • Negligible sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • Negligible humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Industrial temperature range -40 °C to +80 °C
  • Linear output up to 100 % LEL
  • Available with ultra-low thermal drift (ULTD) and test protocol
  • 4-20 mA current-loop transmitter with reverse voltage operation and over-voltage surge protection
  • Supply voltage with reversed bias protection

FES Sensor Technology Gassensoren Hydrogen-Sensor H2-CNI 0V-I & H2-CNI 0V-I ULTD

  • Detection of hydrogen levels up to 100% LEL with 100 ppm resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Industrial temperature range from -40 to +80 °C
  • High mechanical stability
  • Linear output up to 100 % LEL
  • Available with ultra-low thermal drift (ULTD) and test protocol
  • On-board instrumentation amplifier and voltage output
  • Supply voltage with reversed bias protection
FES Sensor Technology Wasserstoffsensor Hydrogen-Sensor H2-CNI 1V Alders

FES Sensor Technology Hydrogen-Sensor H2-CNI 1V

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  •  No humidity-induced base line drift
  •  Applicable in relative humidity (rh) between 0 % to 100 %
  • Ambient temperature range from -10 to +50 °C (optional: other temperature ranges)
  •  Linear output up to 100 % LEL
  •  On-board sensor electronics
  •  Zero-signal voltage adjusted to 1 V for operation with 4-20 mA interface electronics
FES Sensor Technology Wasserstoffsensor Hydrogen-Sensor H2-CNI 1V Alders

FES Sensor Technology Hydrogen-Sensor H2-CNI 0V

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Ambient temperature range from -10 to +50 °C (optional: other temperature ranges)
  • Linear output up to 100 % LEL
  • On-board sensor electronics
FES Sensor Technology Gassensoren Hydrogen-Sensor H2-CNI 12C alders

FES Sensor Technology Hydrogen-Sensor H2-CNI I2C

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Industrial temperature range from -40 °C to +90 °C
  • Linear output up to 100 % LEL
  • On-board digital temperature sensor and EEPROM with I2C®bus connectivity
FES Sensor Technology Gassensoren Hydrogen-Sensor H2-CNI 12C alders

FES Sensor Technology Hydrogen-Sensor H2-CCT 12C

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity‐induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Linear output up to 100 % LEL
  • On‐chip Pt1000 element and heater
  • Industrial temperature range from ‐40 °C to +85 °C

FES Sensor Technology Hydrogen-Sensor H2-CNI with 4-20 mA Transmitter

  • Detection of hydrogen levels up to 100% LEL with 0.25 % resolution in air
  • No sensitivity against typical catalyst poisons such as volatile siloxanes and carbon monoxide
  • Fast response and recovery times
  • No humidity-induced base line drift
  • Applicable in relative humidity (rh) between 0 % to 100 %
  • Ambient temperature range +10 to +30 °C (optional: other temperature ranges)
  • Linear output up to 100 % LEL
  • On-board sensor electronics
  • 4-20 mA current-loop transmitter with reverse voltage operation and overvoltage surge protection

Nissha FIS Inc. Gas sensor SP3-61-00 for Ozone

Usage:Air quality – Ozone/Home appliances
Target gasOzone
DescriptionSensor that is highly sensitive to ozone. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ14.0 x 18.0mm
Weight1.2g

Nissha FIS Inc. Gas sensor SP3S-AQ2-01 for Carbon monoxide (CO) / VOC (Ethanol)

Usage:Automobile – Inside air/Air quality – Air purifiers/Home appliances/Alcohol checker

 

Target gasCO、Ethanol、VOC
DescriptionCompact sensor that is highly sensitive to gas generated in a living space. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ7.6 x 13.4mm
Weight0.6g

Nissha FIS Inc. Gas sensor SP-15A-00 for LPG (Propane, Butane)

Usage:Home gas leak detector

Target gasLPG(Propane, butane)
DescriptionSensor with high selectivity to propane. Circuit design is easier than SB- series.
Sensing principalSemiconductor type
Standard operating conditionHeater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption400mW
FilterNot included
Sizeφ17.0 x 16.5mm
Weight1.75g